For the S8700-series Media Servers only, you can include an additional IPSI in the PN for
control duplication.
Installing the media processor circuit packs
Add the media processor circuit packs to the slots that you designated for media processors.
To install a media processor circuit pack:
1. Insert the TN2602AP circuit pack into the slot that you previously prepared for the media
processor.
2. Push firmly on the faceplate until the circuit pack is properly seated, then close the latch.
3. After about 1 minute, to open the SAT Circuit Packs screen, enter
display circuit-pack cabinetnumber. Verify that the TN2312B circuit packs are
shown in the appropriate slots.
Installing the CLAN circuit packs
Add the CLAN circuit packs to the slots that you designated for CLANs.
To install a CLAN circuit pack:
1. Insert the TN799DP circuit pack into the slot that you previously prepared for the CLAN.
2. Push firmly on the faceplate until the circuit pack is seated, then close the latch.
3. On the SAT, open the Circuit Packs screen using
display circuit-pack cabinetnumber and verify that the TN799DP circuit packs
are shown in the appropriate slots.
Adding cables for the new circuit packs
IPSI circuit packs are connected to an Ethernet switch in the control network. Media processor
and CLAN circuit packs are connected to the customer LAN.
!
Important:
Each of the three types of circuit packs requires an I/O adapter that is connected
Important:
to the backplane amphenol connector. The adapters for the three types of circuit
packs are different and not necessarily interchangeable. Also, the adapters for
the TN2302AP and TN2602AP media processor circuit packs are different.
Ensure that you use the correct adapter that corresponds to each type of circuit
pack.
Connecting IPSI cables
To connect an IPSI slot to the control network:
1. Connect the TN2312BP I/O adapter to the backplane amphenol connector that corresponds
to the slot in which the TN2312BP is installed.
2. Connect a CAT5 or better Ethernet cable to the RJ45 connector on the IPSI adapter.
Conversion Tasks
Issue 2.1 June 2006
1059