Avaya S8100 Series Manual page 1023

Media servers and gateways
Hide thumbs Also See for S8100 Series:
Table of Contents

Advertisement

Performing an integrity check on the second S8720 Media Server
To perform an integrity check on the second S8720 Media Server:
1. On the Maintenance Web Interface, under Diagnostics, click Ping.
The system displays the Ping window.
2. Under Endpoints to Ping, click Other server(s), All IPSIs, UPS(s), Ethernet switches and
click Execute Ping.
If this ping fails, see Maintenance Procedures for Avaya Communication Manager 3.1,
Media Gateways and Servers (03-300432).
3. Click Server > Status Summary.
The system displays the Status Summary window.
4. Verify the following:
Mode: BUSY OUT
Server Hardware: okay
Processes: okay
5. Select Server > Process Status.
The system displays the Process Status window.
6. Under Frequency, click Display Once.
7. Click View.
8. Verify all operations are Up except ENV can be off.
9. Telnet to a device outside the media server and ping the media server.
10. Under IPSI Firmware Upgrades, click IPSI Version.
The system displays the IPSI Version window.
11. Under Query Type, click Query All and click View to verify connectivity to all IPSIs.
On the second S8720 Media Server
Issue 2.1 June 2006
1023

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents