Converting IP-PNC port networks with simplex control to duplicated control
Designating the slot for the duplicated IPSI circuit pack
Designate the slot in which each new IPSI is to be installed. Each of these circuit packs requires
an I/O adapter that is installed on the backplane connector associated with the slot in which the
circuit pack is installed.
The IPSI circuit packs must be placed in the slots specified in the "Secondary, if duplicated
control — S8700 series only" column in the following table.
IPSI slot locations
Carrier/Gateway
G650 stack
SCC1 EPN
MCC1 EPN -- 1 PN
MCC1 EPN -- 2 PNs
MCC1 EPN -- 3 PNs
MCC1 EPN -- 4 PNs
MCC1 EPN -- 5 PNs
1188 Upgrading, Migrating, and Converting Media Servers and Gateways
Slot Number
Primary
A01
A00
- Tone Clock slot (A00)
- Tone Clock slot (A00)
- E02
- Tone Clock slot (A00)
- B02
- D02 (single control)
- E02 (duplicated control)
- Tone Clock slot (A00)
- B02
- C02
- D02 (single control)
- E02 duplicated control)
- Tone Clock slot (A00)
- B02
- C02
- D02
- E02
Secondary, if duplicated
control — S8700 series
only
B01
B01
B01
B01
D01
Control duplication not
supported with 3 PNs.
D01 (duplicated control)
Control duplication not
supported with 4 PNs
D01 (duplicated control)
Control duplication not
supported with 5 PNs