Avaya S8100 Series Manual page 818

Media servers and gateways
Hide thumbs Also See for S8100 Series:
Table of Contents

Advertisement

Migrating a DEFINITY ONE/S8100 to an S8700-Series Media Server with IP-PNC
3. Verify that all the other fields are populated.
4. Press Enter to put the changes into effect.
5. Repeat Steps 1 through 5 for each port network.
Setting IPSI duplication (high-reliability critical-reliability only)
To set IPSI duplication:
1. Type change system-parameters duplication. Press Enter.
2. Set the Enable Operation of IPSI Duplication field to y.
3. Press Enter to put the changes into effect.
Setting the alarm activation level
To set the alarm activation level:
1. Type change system-parameters maintenance. Press Enter.
2. In the CPE Alarm Activation Level field, select warning, minor, or major, depending on
the level that the customer wants. The default is none.
Backing up translations
To back up translations:
1. S8710: Place a formatted flash card in the compact flash drive attached to a USB port.
2. Start a Web browser.
3. Log in as craft or dadmin.
4. Click Launch Maintenance Web Pages.
5. Under Data Backup/Restore, click Backup Now.
6. Select the data sets and the backup method.
If you select Save ACP translations prior to backup, the media server automatically
saves the translations to the hard disk before the media server saves the translations to the
backup media.
7. Click Start Backup to start the backup process.
818 Upgrading, Migrating, and Converting Media Servers and Gateways