24
Determine if the CPUs are in sync.
Note: A dot symbol under the Sync header indicates that the CPUs are in
sync. The word No indicates that the CPUs are not in sync.
If the CPUs
are in sync
are not in sync
25
Determine from the next level of support if you can synchronize the CPUs.
If you
can synchronize the CPUs
cannot synchronize the CPUs
26
Determine if the inactive CPU jammed.
Note: The word yes under the Jam header indicates that the CPU
jammed. The area is blank if the CPU did not jam.
If the inactive CPU
jammed
did not jam
At the CM reset terminal for the INACTIVE CPU
27
To release the jam on the inactive CPU, type
>\RELEASE
and press the Enter key.
RTIF response:
JAM RELEASE DONE
At the MAP terminal
28
To synchronize the CPUs, type
>SYNC
and press the Enter key.
Example of a MAP response:
DMS-100 Family NA100 Recovery Procedures LET0015 and up
System level recovery procedures
Performing a reload-restart
JAM
Do
step 31
step 25
Do
step 26
step 31
Do
step 27
step 28