2-82 System level recovery procedures
Recovering from a dead system in a SuperNode switch
161
162
163
164
165
166
167
168
297-8021-545 Standard 14.02 May 2001
vol_name
is the name of the volume to be reset
If the RSETVOL command
passed
failed
Perform the Allocating recording volumes in the DIRP utility procedure in
Routine Maintenance Procedures . Complete the procedure and return to this
point.
Determine from your next level of support if you need to recover other DIRP
subsystems at this point (for example, JF, OM).
If other DIRP subsystems
require recovery
do not required recovery
Perform the correct procedures in Alarm and Performance Monitoring
Procedures . Complete the procedures, and return to this point.
To determine if the system generated DIRP logs , type
>LOGUTIL;OPEN
DIRP
and press the Enter key.
If the system
generated DIRP logs
did not generate DIRP logs
Refer to the Log Report Reference Manual and take the correct action.
Complete the log report activities and return to this point.
Determine if the attempt to synchronize the clocks in step 64 succeeded.
If synchronization
succeeded
failed
To access the MS Clock level of the MAP display, type
>MS;CLOCK
and press the Enter key.
To synchronize the clocks, type
>SYNC
(continued)
Do
step 162
step 183
Do
step 163
step 166
Do
step 165
step 166
Do
step 169
step 167

Advertisement