Nortel DMS-100 Manual page 146

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

Recovering from a dead system in a SuperNode SE switch
67
68
69
70
71
72
Determine the recovery status of the MSs.
Note: The MS recovery status appears on the right side of the word MS
in the MAP display. Recovery status for each MS can be pending, in
progress, complete, or failed.
If
either MS failed recovery
either MS waits for recovery
MS recovery status is other than
listed here
Wait until both MSs are in recovery progress or completed recovery.
When the MSs do not continue to wait for recovery, go to step 67.
To access the MS Clock level of the MAP display, type
>MS;CLOCK
and press the Enter key.
To synchronize the clocks, type
>SYNC
and press the Enter key.
If the SYNC command
passed
failed
Record the reason for the synchronization failure as shown in the MAP
response. Continue this procedure at step 72 to recover networks and
peripheral modules. Repeat the attempt to synchronize the MS clocks later,
after networks and peripheral modules (PM) are in service.
Determine the type of network equipped on the switch.
If the network type
is 16K ENET only (no external
network cabinet)
is ENET (with external network
cabinet)
is JNET
DMS-100 Family NA100 Recovery Procedures LET0015 and up
System level recovery procedures
Do
step 193
step 68
step 69
Do
step 72
step 71
Do
step 80
step 73
step 84
2-99