5-74 Emergency power conservation recovery procedures
Emergency power conservation
Restoring a SuperNode ENET to duplex operation
22
23
24
25
26
27
297-8021-545 Standard 14.02 May 2001
and press the Enter key.
where
plane_no
is the network plane number (0 or 1)
MAP response:
Request to RTS ENET Plane:0 Shelf:00 submitted.
Request to RTS ENET Plane:0 Shelf:00 passed.
To manually busy all matrix cards in one plane, type
>MATRIX;BSY
plane_no
and press the Enter key.
where
plane_no
is the ENET plane number (0 or 1)
To return all matrix cards in one plane to service, type
>RTS
plane_no
ALL
and press the Enter key.
where
plane_no
is the ENET plane number (0 or 1)
Go to step 31.
To return a single shelf to service, type
>RTS
plane_no
shelf_no
and press the Enter key.
where
plane_no
is the ENET plane number (0 or 1)
shelf_no
is the ENET shelf number (0 to 7)
MAP response:
Request to RTS ENET Plane:0 Shelf:00 submitted.
Request to RTS ENET Plane:0 Shelf:00 passed.
Repeat step 25 for each plane shelf powered down to conserve power. When
you have finished, continue this procedure.
To access the Shelf level for the first ENET shelf you returned to service, type
>SHELF
shelf_no
and press the Enter key.
where
shelf_no
is the ENET shelf number (0 to 7)
(continued)