Nortel DMS-100 Manual page 527

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

5-176 Emergency power conservation recovery procedures
Emergency power conservation
Emergency shutdown of one unit of LCMs
Emergency shutdown of one unit of LCMs
At the MAP terminal
1
2
3
297-8021-545 Standard 14.02 May 2001
WARNING
Potential service interruption or extended outage
Nortel recommends that you contact the
Emergency-Technical Assistance Services (ETAS) or the
next level of support before you perform this procedure.
WARNING
Potential loss of service or extended outage
Perform this procedure only to conserve emergency backup
power. Do not use this procedure or sections of this
procedure for equipment maintenance purposes.
To access the PM level of the MAP display, type
>MAPCI;MTC;PM
and press the Enter key.
To post the LCM for the unit that you will power down, type
>POST
LCM
HOST
and press the Enter key.
where
frame
is the frame number (00 to 99)
pair
is the frame pair number (0 to 1)
Example of a MAP response:
LCM HOST 00 0 InSv Links
Unit 0: InSv
Unit 1: InSv
/RG:1
Drwr:
01 23 45 67 89 01 23 45 67 89
To manually busy the LCM unit, type
>BSY
UNIT
unit_no
and press the Enter key.
(continued)
frame
pair
OOS: Cside 0 Pside 0
/RG:0
11 11 11 11 11
RG:Pref 0 InSv
Stby 1 InSv

Advertisement

Table of Contents
loading

Table of Contents