Nortel DMS-100 Manual page 188

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

Recovering link peripheral processors
Example of a MAP response:
LIM
1
SysB
Unit0: SysB
Unit1: SysB
22
Determine if the LIM unit is system-busy, resource not available.
Note: When a LIM unit is system-busy, resource unavailable the
indication SysB (RU) appears in the MAP response. This message
appears to the right of the LIM unit number.
If
either LIM unit is SysB (RU)
neither LIM unit is SysB (RU) step 85
To clear the fault, refer to the Clearing a PM LIM critical alarm procedure in
23
Alarm and Performance Monitoring Procedures .
When you have completed the procedure, return to this point.
24
To access the F-bus level of the MAP display, type
>FBUS
and press the Enter key.
25
Determine if the F-buses are in-service.
If
both F-buses are InSv
one or both F-buses are SysB
26
To manually busy the system-busy F-bus, type
>BSY
FBUS
and press the Enter key.
where
fbus_no
is the number of the F-bus (0 or 1) that you want to manually busy
27
To return the F-bus to service, type
>RTS
FBUS
and press the Enter key.
where
DMS-100 Family NA100 Recovery Procedures LET0015 and up
Node level recovery procedures
Links_OOS
Taps_OOS
6
6
fbus_no
fbus_no
5
5
Do
step 23
Do
step 18
step 26
3-21
(continued)