Restoring the ELPP LIM to duplex operation
and press the Enter key.
where
lim_no
is the number of the LIM that you post (0 to 16)
Example of a MAP response:
LIM 0
ISTB
Unit0: ManB
Unit1: ISTb
4
To load the LIM unit that you powered up in step 1, type
>LOADPM UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the LIM unit (0 or 1)
5
To return to service the LIM unit that you powered up in step 1 to service, type
>RTS
UNIT
and press the Enter key.
where
unit_no
is the number of the LIM unit (0 or 1)
6
To access the LIS level of the MAP display, type
>LIS lis_no
and press the Enter key.
where
lis_no
is the number of the LIS (1, 2, or 3)
7
To return the F-bus to service, type
>RTS
FBUS
and press the Enter key.
where
fbus_no
is the number of F-bus (0 or 1)
Note: F-bus 0 and F-bus 1 exist for each LIS level (1, 2, and 3).
8
Repeat steps 6 and 7 for the F-bus on each LIS level (1, 2, and 3). When the
F-bus for each LIS has been returned to service, go to step 9.
9
Repeat steps 1 to 7 for each ELPP that you converted to simplex operation to
conserve emergency power. Once all ELPPs have been restored, go to step
10.
DMS-100 Family NA100 Recovery Procedures LET0015 and up
Emergency power conservation recovery procedures
Emergency power conservation
OOS
OOS_Taps
Links
LIS1
2
12
2
.
unit_no
fbus_no
LIS2
LIS3
12
12
.
.
5-21
(continued)