Nortel DMS-100 Manual page 164

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

Recovering from a dead system in a SuperNode SE switch
180
181
182
At the CM RESET terminal for the INACTIVE CPU
183
At the MAP terminal
184
Determine if the CPUs are in sync.
Note: A dot symbol under the Sync header indicates that the CPUs are in
sync. The word no indicates that the CPUs are not in sync.
If the CPUs
are in sync
are not in sync
Contact the next level of support to determine if you can synchronize the
CPUs.
If you
can synchronize the CPUs
can not synchronize the CPUs
Determine if the inactive CPU jammed.
Note: The word yes under the JAM header indicates a jammed inactive
CPU. The area is blank if the inactive CPU is not jammed.
If the inactive CPU
is jammed
is not jammed
To release the jam on the inactive CPU, type
>\RELEASE
JAM
and press the Enter key.
RTIF response:
JAM RELEASE DONE
To synchronize the CPUs, type
>SYNC
and press the Enter key.
If the response
indicates the SYNC command was
successful
DMS-100 Family NA100 Recovery Procedures LET0015 and up
System level recovery procedures
Do
step 186
step 181
Do
step 182
step 186
Do
step 183
step 184
Do
step 179
2-117
(continued)