5-106 Emergency power conservation recovery procedures
Emergency power conservation
Emergency shutdown of one DMS SuperNode CM plane
At the CM shelf
16
17
297-8021-545 Standard 14.02 May 2001
WARNING
Static electricity damage
Wear a wrist strap that connects to the wrist-strap grounding
point of a frame supervisory panel (FSP) to handle circuit
cards. The wrist strap protects the cards against static
electricity damage.
WARNING
Possible loss of service
Make sure that the CM runs on the active CPU clock. A cold
restart or a system image reload can occur if you power down
the inactive side of the CM while the CM runs on the clock
of the inactive CPU.
Power down the inactive CPU as follows:
Press down and release the power switch on the faceplate of the NT9X30
power converter. The faceplate of the NT9X30 power converter is on the
inactive side of the CM shelf.
Note: Slots 4F to 6F contain the power converter for CPU 0. Slots 36F
to 38F contain the power converter for CPU 1.
Press down and release the power switch on the faceplate of the NT9X31
power converter. The faceplate of the NT9X31 power converter is on the
inactive side of the CM shelf.
Note: Slots 1F to 3F contain the power converter for CPU 0. Slots 33F
to 35F contain the power converter for CPU 1.
The procedure is complete.