Nortel DMS-100 Manual page 438

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

RETAIN option is OFF.
Next scheduled dump is FRIDAY at 22:00 hours.
Next image to be dumped S01DIMAGE.
If a recent office image
is available
is not available
5
Use the procedure Recording an office image on an SLM
diskin Routine Maintenance Procedures to take an office
image.
6
Power down all maintenance trunk modules in the office. Do
not power down maintenance trunk modules that contain
cards that affect service. To power down all maintenance
trunk modules, perform the procedure
Note: Cards that affect service include digitone receiver cards
(NT2X48), and centralized-automatic message accounting
(CAMA) cards(NT2X66 and NT2X66). Cards that affect
service also include digital-recorded announcement machine
(DRAM) cards.
7
Power down one line module controller (NT2X14 shelf) in
each double-bay line module pair in the office. To power down
a NT2X14 shelf, perform the procedure Emergency shutdown
of one half a line module pair in this document.
8
Do not power down any LCMs as both units are designed to
draw power from either the unit 0 or the unit 1 power converter
and no power savings will be realized by powering down one
power converter of a LCM.
9
Determine which plane of the ENET or JNET is to be powered
down and power down the same unit number of the LGC, LTC,
or DTC.
If the plane to be
powered down is
Plane 0
Plane 1
DMS-100 Family NA100 Recovery Procedures SN09 (DMS) and up
Do
step 6
step 5
Do
Power down unit 0 of each of the following:
all line group controllers (LGC)
all line trunk controllers (LTC)
all digital trunk controllers (DTC)
Power down unit 1 of each of the following:
all line group controllers (LGC)
all line trunk controllers (LTC)
all digital trunk controllers (DTC)
Emergency power 5-89