4-80 Recovery procedures for individual devices and services
Recovering CCS7 linksets
9
10
11
12
13
14
297-8021-545 Standard 14.02 May 2001
(continued)
Determine the state of the posted LIU7 or MLIU.
If the state of the LIU7 or MLIU is
InSv
Offl
ManB
To force the LIU7 or MLIU to busy, type
>BSY
FORCE
and press the Enter key.
To return the LIU7 or MLIU to service, type
>RTS
FORCE
and press the Enter key.
If the RTS command
passed
failed
To reset the LIU7 or MLIU, type
>PMRESET
and press the Enter key.
If the PMRESET command
passed
failed
To load the LIU7 or MLIU, type
>LOADPM
and press the Enter key.
If the LOADPM command
passed
failed
To force the LIU7 or MLIU to return to service, type
>RTS
FORCE
Do
step 15
step 10
step 11
Do
step 15
step 12
Do
step 14
step 13
Do
step 14
step 44