Nortel DMS-100 Manual page 516

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

Emergency shutdown of one SuperNode SE CM plane
16
Determine if the primary autoload device is on the active CPU or inactive CPU
side of the switch.
If the primary autoload device
is on the same plane with the active CPU
is on the same plane with the inactive CPU
17
To change the primary autoload device to a device on the same side of the
switch as the active CPU, type
>AUTOLD SLM
and press the Enter key.
where
Example of a MAP response:
New autoload route has been set.
18
To access the SLM that corresponds to the inactive CPU, type
>IOD;SLM
and press the Enter key.
where
Example of a MAP display:
Emergency power conservation recovery procedures
slm_number
slm_number
is the number of the active CPU (0 or 1)
device_type
is the number of SLM device (DISK or TAPE)
slm_number
slm_number
is the number of the inactive CPU (0 or 1)
DMS-100 Family NA100 Recovery Procedures LET0015 and up
Emergency power conservation
device_type
5-165
(continued)
Do
step 18
step 17