2-10 System level recovery procedures
Booting a DMS switch
At the CM reset terminal for the INACTIVE CPU
23
24
25
297-8021-545 Standard 14.02 May 2001
(continued)
DANGER
BOOT command
A CPU mismatch occurs if you use the BOOT command
when the CPUs are InSync. Mismatch handling and
mismatch recovery can change the state of one of both CPUs.
For example, the active CPU can reset the mate CPU during
mismatch handling or recovering. Any in-progress
commands such as BOOT terminate, as a result.
To boot the inactive CPU, type
>\BOOT
SLMslm_noT
and press the Enter key.
where
slm_no
is the number of the SLM (0 or 1) with the required tape load
Example input:
>\BOOT
SLM0T
RTIF response:
BOOT Please confirm: (YES/NO)
To confirm the command, type
>YES
and press the Enter key.
RTIF response:
BOOT INITIATED
To release the jam on the inactive CPU, type
>\RELEASE
JAM
and press the Enter key.
RTIF response:
JAM RELEASE DONE