Nortel DMS-100 Manual page 420

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

Restoring a SuperNode ENET to duplex operation
SYSTEM
Shelf
00
4
To identify the message switch card chain that connects to each shelf that
was powered down to conserve emergency power, type
>TRNSL
and press the Enter key.
where
plane_no
is the ENET plane number (0 or 1)
shelf_no
is the ENET shelf number (0 to 7)
Example of a MAP response:
Request to TRNSL ENET Plane:0 Shelf:00 passed.
ENET Plane:0 Shelf:00 MS:0 and 1 Card:20 Link:00
Port:00
5
Note the card number and link number.
6
To access the MS Shelf level of the MAP display, type
>MS;SHELF;CHAIN
and press the Enter key.
where
card_no
is the card number you noted in step 5
7
To return the head card in the associated chain on MS 0 to service, type
>RTS
0
and press the Enter key.
where
link_no
is the link number you noted in step 5
8
To return the head card in the associated chain on MS 1 to service, type
>RTS
1
and press the Enter key.
where
link_no
is the link number you noted in step 5
9
Repeat steps 4 to 8 for each plane shelf you powered down to conserve
power. When you have finished, return to this point and continue the
procedure.
Emergency power conservation recovery procedures
Emergency power conservation
Plane 0
.
plane_no
shelf_no
card_no
LINK
link_no
LINK
link_no
DMS-100 Family NA100 Recovery Procedures LET0015 and up
(continued)
Plane 1
.
5-71

Advertisement

Table of Contents