Nortel DMS-100 Manual page 70

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

Performing a cold restart
At your current location
1
Determine if you can use a MAP terminal to execute the restart.
If you
can use a MAP terminal
cannot use a MAP terminal
At the MAP terminal
2
To access the CI level of the MAP display, type
>QUIT ALL
and press the Enter key.
3
To restart the switch, type
>RESTART
COLD ACTIVE
and press the Enter key.
Example of a MAP response:
DMS-100 Family NA100 Recovery Procedures LET0015 and up
System level recovery procedures
Performing a cold restart
WARNING
Contact your next level of support
Do not attempt this procedure before you contact the next
level of support.
WARNING
Loss of Service
All calls drop during a cold restart.
WARNING
Extended service interruption
Make sure you execute the restart from a MAP terminal.
Depending on the severity of the problem, MAP terminals
can be out of service. If a MAP terminal is not available,
perform the restart from the CM reset terminals.
Do
step 2
step 6
2-23
(continued)