2-62 System level recovery procedures
Recovering from a dead system in a SuperNode switch
41
42
43
At the IOD frame
44
45
46
47
297-8021-545 Standard 14.02 May 2001
To boot the active CPU, type
>\BOOT
SLM
slm_no
and press the Enter key.
where
slm_no
is the number of the SLM (0 or 1) that contains the most recent image
file
Example input:
>\BOOT
SLM
0
RTIF response:
Please confirm: (YES/NO)
To confirm the command, type
>YES
and press the Enter key.
RTIF response:
JAM DONE
Wait until A1 flashes on the reset terminal for the active CPU to determine if
the switch booted.
If A1
flashes
does not flash after 15 min
Turn on the power converters on input/output controller 0 (IOC 0).
Note: The vintage of IOC determines if the IOC is equipped with one or
two power converters.
Press the reset button on one of the IOC power converters. Hold the reset
button and lift the FSP circuit breaker switch for IOC 0.
Release the reset button.
Turn on the power inverter that supplies the operator MAP.
(continued)
Do
step 44
step 183