Nortel DMS-100 Manual page 53

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

2-6 System level recovery procedures
Booting a DMS switch
7
8
At the CM reset terminal for the INACTIVE CPU
9
10
11
12
297-8021-545 Standard 14.02 May 2001
(continued)
YES
To confirm the command, type
>YES
and press the Enter key.
RTIF response:
RESTART DONE
Verify that the CPUs are out of sync.
If A1
flashes
does not flash after 15 min
Access the CM level of the MAP display, by typing
>MAPCI;MTC;CM
and pressing the Enter key.
Perform a drop CPU synchronization, by typing
>DpSync
and pressing the Enter key.
Note: The DpSync command must be used before you boot a DMS switch
from any SLM device, tape or disk.
Determine which CPU to boot.
If the CPU is
active
inactive
Determine the boot device (the most recent valid image).
If the boot device is from an
SLM tape
SLM disk
Do
step 11
Repeat step 6, or contact your
next level of support.
Do
step 12
step 21
Do
step 13
step 17

Advertisement

Table of Contents