Nortel DMS-100 Manual page 148

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

Recovering from a dead system in a SuperNode SE switch
81
82
83
At the JNET shelf
84
From the MAP display, determine the recovery status of the network.
Note: Network recovery status appears on the right side of the word NET
in the MAP display. Recovery status can be pending, in progress,
complete, or failed.
If the status of any network ele-
ment
failed
is pending
is other than listed here
Wait until network elements pending recovery are not present.
Go to step 81.
Perform the procedure How to recover the Enhanced Network in this
document to manually recover the ENET.
Complete the procedure and return to this point.
Go to step 80.
DANGER
Static electricity damage
Wear a wrist strap that connects to the wrist-strap grounding
point to handle circuit cards. A grounding point is on the
frame supervisory panel (FSP) or the modular supervisory
panel (MSP). The wrist strap protects the cards against static
electricity damage.
WARNING
Static electricity damage
Wear a wrist strap that connects to the wrist-strap grounding
point to handle circuit cards. A grounding point is on the
frame supervisory panel (FSP) or the modular supervisory
panel (MSP). The wrist strap protects the cards against static
electricity damage.
Locate the first junctured network shelf to recover.
DMS-100 Family NA100 Recovery Procedures LET0015 and up
System level recovery procedures
Do
step 83
step 82
step 96
2-101
(continued)