Nortel DMS-100 Manual page 484

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

Emergency shutdown of one LGC, LTC, and DTC unit
If to
leave both units of this XPM in service and proceed
to the next XPM
7
To confirm the prompt to switch the activity of the unit, type
>YES
and press the Enter key.
The system runs an audit before the SWACT to determine the ability of the
inactive unit to accept activity correctly.
Note: A maintenance flag ("Mtce" in the following example) appears when
maintenance tasks are in progress. Wait until the flag disappears before
you proceed with the next maintenance action.
Example of a MAP response:
XPM 0 ISTb
Unit0:
Unit1:
8
To manually busy the inactive unit of the XPM, type
>BSY
and press the Enter key.
where
9
To identify the network type and network links that associate with the manual
busy XPM unit, type
>TRNSL C
and press the Enter key.
Example of a MAP response:
LINK 0: NET 0 1 0;CAP MS;Status:OK
LINK 1: NET 1 1 0;CAP MS;Status:OK
LINK 2: NET 0 1 4;CAP MS;Status:OK
LINK 3: NET 1 1 4;CAP MS;Status:OK
LINK 4: NET 0 1 8;CAP MS;Status:OK
...
LINK 31 NET 1 1 60;CAP MS;Status:OK
Note: Links 5 to 30 do not appear.
Example of a MAP response:
Emergency power conservation recovery procedures
Links_OOS:
Act
ISTb
Inact InSv
UNIT
unit_no
unit_no
is the PM unit number (0 or 1)
DMS-100 Family NA100 Recovery Procedures LET0015 and up
Emergency power conservation
CSide 0, PSide 0
Mtce
Mtce
5-133
(continued)
Do
step 2

Advertisement