5-82 Emergency power conservation recovery procedures
Emergency power conservation
Restoring a SuperNode SE ENET to duplex operation
16
17
18
19
20
297-8021-545 Standard 14.02 May 2001
Request to MAN BUSY ENET Plane:0 Shelf:00 submitted.
Request to MAN BUSY ENET Plane:0 Shelf:00 passed.
To load software into the shelf, type
>LOADEN
plane_no
and press the Enter key.
where
plane_no
is the ENET plane number (0 or 1)
shelf_no
is the ENET shelf number (0 to 7)
MAP response:
WARNING Any software load in the ENET will be destroyed.
Please confirm ("YES" or "NO"):
To confirm the command, type
>YES
and press the Enter key.
To return the shelf to service, type
>RTS
plane_no
shelf_no
and press the Enter key.
where
plane_no
is the network plane number (0 or 1)
shelf_no
is the ENET shelf number (0 or 1)
MAP response:
Request to RTS ENET Plane:0 Shelf:00 submitted.
Request to RTS ENET Plane:0 Shelf:00 passed.
To access the ENET shelf level, type
>SHELF
shelf_no
and press the Enter key.
where
shelf_no
is the ENET shelf number (0 or 1)
MAP response:
Request to RTS ENET Plane:0 Shelf:00 submitted.
Request to RTS ENET Plane:0 Shelf:00 passed.
To manually busy all matrix cards, type
>BSY
plane_no
ALL
and press the Enter key.
shelf_no
(continued)