Emergency shutdown of one unit of MSB7s
where
n
is the network module number recorded in step 12
15
To manually busy the first network link, type
>BSY
plane_no
and press the Enter key.
where
plane_no
is the network plane (0 or 1)
link_no
is the network link number
16
Repeat steps 14 and 15 until all links between the manual busy MSB7 unit
and the network are manual busy. Go to step 17.
17
Wait 2 min. Go to step 25.
18
Determine the speech link numbers that associate with the manual busy
MSB7 unit. Even numbered speech links associate with unit 0. Odd
numbered speech links associate with unit 1.
Note: Speech links 0, 2, 4 and 6 associate with unit 0 in the ENET
example response in step 9. Speech links 1, 3, 5, and 7 associate with
MSB7 unit 1.
19
Record the ENET plane number, shelf number, card number, and network link
number that associate with the ENET. Perform this procedure for each
speech link recorded in step 18.
Note: Speech link 3 associates with ENET plane 1, shelf 0, card 23, and
network link number 01. This association appears in the ENET example
response in step 9.
20
To access the NET level of the MAP display, type
>NET
and press the Enter key.
21
To access the MAP display for the first speech link and the ENET card that
associates with this link, type
>SHELF
shelf_no;
and press the Enter key.
where
shelf_no
is the ENET shelf number
card_no
is the ENET card number
22
To deload traffic from the ENET card, type
>DELOAD
plane_no
and press the Enter key.
DMS-100 Family NA100 Recovery Procedures LET0015 and up
Emergency power conservation recovery procedures
Emergency power conservation
link_no
CARD
card_no
SET
5-183
(continued)