Recovering AMA data without DIRP block numbers
where
file_name
41
Determine the number of the DPP block that the data center received before
the DPP power failure. To determine the number, filter the information that
you obtained in step 11. To begin, type
>FILTER
and press the Enter key.
where
structure_code
Example input:
>FILTER
Example of a MAP display:
>>>ADDING....STRUCTURE CODE: 00700
42
Enter the call code that you obtained in step 11.
Example input:
>043C
In response, the filter function prompts you for a number of fields.
43
To fill in the ORIG NPA field, use the originating numbering plan area (NPA)
value that you obtained in step 11. If the value contains zeros, you must
define the field with all the zeros included.
Example input:
>602* or 602C
To continue to the next field, press the Enter key.
Note: The * is a wild card. The * matches any variable.
44
To fill in the ORIG NUMBER field, use the originating number value that you
obtained in step 11. If the value contains zeros, define the field with all the
zeros included.
Example input:
>9422640* or 9422640C
To continue to the next field, press the Enter key.
Note: The * is a wild card. The * matches any variable.
45
To fill in the TERM NPA field, use the terminating numbering plan area (NPA)
value you obtained in step 11. If the value contains zeros, define the field with
all the zeros included.
Example input:
>00602* or 00602C
Recovery procedures for individual devices and services
is the AMA file name that you noted in step 25
ADD
'structure_code
is the structure code you obtained in step 11
ADD
'00700
RECORD CODE:
CALL CODE:
DMS-100 Family NA100 Recovery Procedures LET0015 and up