Nortel DMS-100 Manual page 278

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

Recovering AMA data without DIRP block numbers
This command filters through the parallel file. The command searches for the
defined record. One record matches the data that you entered into the filter.
When the utility locates the record, the block number that the data center
received before the DPP power failure appears.
Example of a MAP display:
>>>BLOCK NO:15
*HEX ID = AA STRUCT CODE:00700*
SENSOR TYPE: **** SENSOR ID: ******** REC OFC TYPE: ****
REC OFC ID: ******** DATE: ****** TIMING IND: ******
STUDY IND: ******** ANSWER: ** SERV OBSERVED: **
OPER ACTION: ** SERV FEAT: **** ORIG NPA; 602C
ORIG NO: 9422640C OVERSEAS IND: **
TERM NO: 8385792C TIME: ******** ELAPSED TIME: **********
IC/INC PREFIX: ****** CC DATE: ****** CC TIME: 0000152C
ELAPSED CC: ********** IC/INC EVENT: **** TRK ROUTING: **
DIALING: ** ANI: **
52
Note the block number that appears on the screen. In the example in step
51, the block number is 15.
53
To check the full block against the block the data center provided, type
>DUMP
and press the Enter key.
where
block_number
54
To disable the FILTER ADD command you used in step 41, type
>FILTER
and press the Enter key.
55
To delete the FILTER ADD command you used in step 41, type
>FILTER
and press the Enter key.
where
structure_code
Example input:
>FILTER
56
Determine the number of the DPP block the data center received after the
DPP power failure. To determine the number, filter the information you
obtained in step 13. To begin, type
>FILTER
and press the Enter key.
where
Recovery procedures for individual devices and services
CALL
DETAILS
is the number that you recorded in step 52
DISABLE
DELETE structure_code
is the structure code you obtained in step 11
DELETE
'00700
ADD
'structure_code
DMS-100 Family NA100 Recovery Procedures LET0015 and up
CALL TYPE:****
TERM NPA; 00602C
block_number
1
1
4-71
(continued)

Advertisement

Table of Contents
loading