Emergency shutdown of one SuperNode SE CM plane
and press the Enter key.
RTIF response:
JAM DONE
At the MAP terminal
9
To drop synchronization, type
>DPSYNC
and press the Enter key.
Example of MAP display response:
About to drop sync with CPU n active.
The inactive CPU is
Do you want to continue?
Please confirm ("YES","Y", "NO", or "N")
10
To confirm the command, type
>YES
and press the Enter key.
At the CM reset terminal for the inactive CPU
11
Wait until A1 flashes on the reset terminal for the inactive CPU.
At the MAP terminal
12
To determine if the CM runs on the active CPU clock, type
>INSYNC
and press the Enter key.
Example of a MAP response:
Emergency power conservation recovery procedures
Note: Allow 5 min for A1 to begin to flash.
WARNING
Possible loss of service
Make sure that the CM runs on the active CPU clock. Do
not power down the inactive side of the CM while the CM
runs on the inactive CPU clock. Failure to follow this
procedure can cause a cold restart or a system image reload.
DMS-100 Family NA100 Recovery Procedures LET0015 and up
Emergency power conservation
JAMMED.
: