Emergency shutdown of one SuperNode SE CM plane
and press the Enter key.
Example of a MAP display:
PORT0:
PORT1:
21
To manually busy the port that corresponds to the inactive CPU, type
>BSY
and press the Enter key.
where
Example input:
>BSY 0
and press the Enter key.
Example of a MAP response:
Maintenance action submitted.Passed.
Example of a MAP display:
PORT0:
PORT1:
Emergency power conservation recovery procedures
PMC 0
.
pbsy
WARNING
Possible loss of service
Make sure that you busy the MC that corresponds to the
inactive CPU. If you power down the plane with the wrong
MC busied you will cause a warm restart.
pmc_number
PORT port_number
pmc_number
is the number of the peripheral message controller (PMC) (0 or 1)
port_number
is the number of the inactive CPU (0 or 1)
PORT 0
PMC 0
istb
.
mbsy
DMS-100 Family NA100 Recovery Procedures LET0015 and up
Emergency power conservation
5-167