Nortel DMS-100 Manual page 319

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

4-112 Recovery procedures for individual devices and services
Recovering enhanced link peripheral processors
26
27
28
29
30
297-8021-545 Standard 14.02 May 2001
Note: For ELPPs F-bus 0 and F-bus 1 exist for each LIS level (1, 2, and 3).
Determine if the F-buses are in-service.
If
all F-buses are InSv
a minimum of one F-bus is
SysB
To manually busy the system busy F-bus, type
>BSY
FBUS
fbus_no
and press the Enter key.
where
fbus_no
is the number of the F-bus you wish to manually busy
To return the F-bus to service, type
>RTS
FBUS
fbus_no
and press the Enter key.
where
fbus_no
is the number of the F-bus that you wish to return to service
If the RTS command
passed
failed
Determine if another F-bus is system busy.
If
all other F-buses are InSv
another F-bus is SysB
To access the next LIS level, type
>NEXT
and press the Enter key.
If
you have already accessed this
LIS level
(continued)
Do
step 18
step 27
Do
step 29
step 31
Do
step 30
step 27
Do
step 18

Advertisement

Table of Contents
loading

Table of Contents