Recovering Ama Data Without Dirp Block Numbers - Nortel DMS-100 Manual

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

Application
Use this procedure to recover automatic message accounting (AMA) data. Use
this procedure after a fault on a distributed processing peripheral (DPP)
disrupts recording to the DPP. The fault consists of inaccessible data that the
DPP collected and stored earlier. The data is inaccessible because the DIRP
data block numbers do not appear on the DIRP101 logs. This procedure shows
you how to determine the DIRP block numbers of the data that the DPP did not
record. This procedure shows you how to retrieve the data from the parallel
recording device and copy the data to tape.
Action
The following flowchart is a summary of this procedure. Use the instructions
in the step-action table that follows the flowchart to perform the procedure.
Recovery procedures for individual devices and services 4-59

Recovering AMA data without DIRP block numbers

DMS-100 Family NA100 Recovery Procedures LET0015 and up