Emergency shutdown of one DMS SuperNode CM plane
15
Emergency power conservation recovery procedures
and press the Enter key.
Example of a MAP display
MC 0
MC 1
.
.
WARNING
Loss of service
Make sure that you busy the message controller that
corresponds to the inactive CPU. A warm restart occurs if
you power down the plane with the wrong MC busied.
To manually busy the MC that corresponds to the inactive CPU, type
>BSY
mc_number
and press the Enter key.
where
mc_number
is the number of the MC (0 or 1) on the inactive side
Example of a MAP display:
Maintenance action submitted.
MC busied OK.
DMS-100 Family NA100 Recovery Procedures LET0015 and up
Emergency power conservation
5-105
(continued)