4-62 Recovery procedures for individual devices and services
Recovering AMA data without DIRP block numbers
6
7
8
297-8021-545 Standard 14.02 May 2001
and press the Enter key.
where
first_sequence_no
is the sequence number that the data center received before the DPP
power failure occurred. The data center supplies this number (see
step 1).
Example of a MAP display:
00 00 00 00 00 00 00 00 12 25 11 15
07BA 0000 0040 0000 AA00 700C 043C 036C 0602 091C 036C
0602 091C 0021 3C00 000C 0200 000C 1C0C 1C00 0C60 2C82
0780 1C1C 0060 2C83 8579 2C00 0015 2C00 0000 000C 1010
301C 0000 0023 0C00 0838 8C
In the office records, note the time and date that is on the first line of the AMA
data block.
For example:
DATE=12 25TIME=11 15
To obtain a print of the DPP AMA block that the data center received after the
DPP power failure, type
>IDXMAINT
EXAMINE
and press the Enter key.
where
last_sequence_no
is the sequence number that the data center received after the end of
the DPP power failure. The data center supplies this number (see step
1).
Note: The sequence numbers this document refers to are DPP reference
numbers. The DMS or data center do not assign these sequence
numbers.
Example of a MAP display:
00 00 00 00 00 00 00 00 12 25 11 15
07BA 0000 0040 0000 AA00 700C 043C 036C 0602 091C 036C
0602 091C 0021 3C00 000C 0200 000C 1C0C 1C00 0C60 2C82
0780 1C1C 0060 2C83 8579 2C00 0015 2C00 0000 000C 1010
301C 0000 0023 0C00 0838 8C
In the office records, note the time and date that is on the first line of the AMA
data block.
For example:
DATE=12 25TIME=11 15
AMA
PACKED
last_sequence_no
(continued)
00
00