3-30 Node level recovery procedures
Recovering link peripheral processors
65
66
67
68
69
70
297-8021-545 Standard 14.02 May 2001
To post the system-busy APUs that failed to recover, type
>POST
APU
apu_nos
and press the Enter key.
where
apu_nos
are the numbers of the system-busy APUs (0 to 511)
Note: Use a space to separate each number.
Example input
>POST
APU
101
To manually busy the APUs in the posted set, type
>BSY
ALL
FORCE
and press the Enter key.
To load the posted APU, type
>LOADPM
and press the Enter key.
If the LOADPM command
passed
failed
To return the APU to service, type
>RTS
and press the Enter key.
If the RTS command
passed, but not all APUs in the
posted set are in service
passed and all APUs in the post-
ed set are in service
failed
To display the next APU in the posted set, type
>NEXT
and press the Enter key.
Go to step 67.
To post the system-busy VPUs that failed to recover, type
>POST
VPU
vpu_nos
and press the Enter key.
(continued)
102
103
104
105
Do
step 68
step 85
Do
step 69
step 18
step 85
106
107
108

Advertisement

Table of Contents
loading