5-118 Emergency power conservation recovery procedures
Emergency power conservation
Emergency shutdown of one enhanced network plane
22
23
24
297-8021-545 Standard 14.02 May 2001
To access the F-bus level, type
>MS;SHELF;CARD 12
and press the Enter key.
WARNING
Potential loss of service
To avoid service interruptions, make sure the proper F-bus
and F-bus taps for the LIU cards, powered by the NT9X30
card, are busied out.
To busy the F-bus connected the ENET plane that you want to power down,
type
>BSY
ms_no
FBUS
and press the Enter key.
where
ms_no
is the message switch number. Enter 0 for ENET plane 0, or 1 for
ENET plane 1.
To busy the associated F-bus taps for the other F-bus, type
>BSY
ms_no
TAP
and press the Enter key.
where
fbus_no
is the message switch number NOT entered in step 23
tap_no
is the tap number. Enter 0 for ENET plane 0, or 11 for ENET plane 1.
tap_no
(continued)