The preceding figure shows a MAP display during the identification of a DTC
as part of the loading process. The loading process reports the status to the
DTC. The message gives the DTC a node number. The DTC uses the node
number to communicate with the DMS-core. The process can last from 2 s to
a maximum of 1 min.
Figure 1-12 MAP display of the DMS-core that queries the ROM firmware of a
DTC
CM
MS
IOD
DTC
0
Quit
PM
2
Post_
DTC
3
Listset
4
DTC
5
Trnsl_
Unit0: Act
6
Tst_
Unit1: Inact
7
Bsy_
8
RTS_
9
OffL
10
LoadPM_
11
Disp_
12
Next
13
SwAct
14
QueryPM
15
16
17
Perform
18
TEAM22
Time 18:35
The preceding figure shows a MAP display of the load process. The load
process performs a ROM/RAM query to determine the ROM firmware that is
present in the DTC. The ROM/RAM query is necessary before the ROM tests
begin because there are different ROM tests for different firmware. This query
lasts less than 1 min.
DMS-100 Family NA100 Recovery Procedures LET0015 and up
Net
PM
CCS
6LCM
2 RSC
*C*
*C*
SysB
ManB
OffL
10
0
3
0
0
SysB
Links_OOS:
SysB
Mtce
SysB
Mtce
System recovery controller 1-23
Lns
Trks
110 GC
*C*
CBsy
ISTb
22
11
1
0
0
0
CSide0,PSide0
ROM/RAM Query
ROM/RAM Query
Ext
APPL
InSv
12