2-98 System level recovery procedures
Recovering from a dead system in a SuperNode SE switch
64
65
66
297-8021-545 Standard 14.02 May 2001
To enter the correct date, type
>SETDATE
dd
mm
and press the Enter key.
where
dd
is the day (01 to 31)
mm
is the month (01 to 12)
yyyy
is the year
Example input:
>SETDATE
12
07
Example of a MAP response:
setdate 12 07 1996
Warning:There is an automated TOD clock change request
scheduled on:1996/10/30 at 1:00 (see table
DSTTABLE).
Do you want to proceed with this request?
Please confirm ("YES", "Y", "NO", or "N"):
To confirm the command, type
>Y
and press the Enter key.
Example of a MAP response:
Date is THU.
12/JUL/1996
To access the SRSTATUS level of the MAP display, type
>MAPCI;MTC;SRSTATUS
and press the Enter key.
Example of a MAP display:
SRSTATUS
OVERALL STATUS Pend:
0
Quit
VIEW: SYSTEM
2
View_
Pend InPrg
3
List_ MS
0
4
NET
0
5
SER1
0
6
SER2
1
7
SER3
11
8
9
SRSTATUS:
yyyy
1996
00:00:00
18%
InProg: 9%
Comp
Fail
0
2
0
IOD
0
6
0
Other 21
1
6
0
1
60
1
8
30
1
(continued)