Emergency shutdown of one LGC, LTC, and DTC unit
Emergency shutdown of one LGC, LTC, and DTC unit
At the MAP terminal
1
To access the PM level of the MAP display, type
>MAPCI;MTC;PM
and press the Enter key.
2
To post the PM for the unit that you will power down, type
>POST
and press the Enter key.
where
Example of a MAP response:
DTC
Unit0:
Unit1:
Emergency power conservation recovery procedures
CAUTION
Potential service interruption or extended outage
Nortel recommends that you contact the Emergency
Technical Assistance Services (ETAS) or the next level of
support before you perform this procedure.
CAUTION
Potential loss of service or extended outage
Perform this procedure only to conserve emergency
backup power. Do not use this procedure or sections of
this procedure for equipment maintenance purposes.
pm_type
pm_no
pm_type
is the PM type (LGC, LTC, or DTC)
pm_no
is the PM identification number (0 to 999)
0 ISTb
Links_OOS: CSide
Act
Inact
DMS-100 Family NA100 Recovery Procedures LET0015 and up
Emergency power conservation
0 , PSide
InSv
InSv
5-131
(continued)