Recovery procedures for individual devices and services
Checking for message throughput
25
Force the HLIU to busy by typing
>BSY
FORCE
and pressing the Enter key.
26
Reset the HLIU by typing
>PMRESET
and pressing the Enter key.
If the PMRESET command
passed, and the HLIU is ManB
failed, and the HLIU is ManB
27
Reload the HLIU by typing
>LOADPM
and pressing the Enter key.
If the LOADPM command
passed
failed
28
Return the HLIU to service
>RTS
If the RTS command
passed
failed
29
Post the HSLR by typing
>POST
HSLR
and pressing the Enter key.
where
liu_no
is the number of the HSLR (0 to 750) associated with the link you
chose in step 12
If the state of the HSLR is
SysB or Offl
ManB
InSV
DMS-100 Family NA100 Recovery Procedures LET0015 and up
Do
step 28
step 27
Do
step 28
step 54
Do
step 29
step 54
liu_no
Do
step 30
step 31
step 36