Nortel DMS-100 Manual page 228

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

Recovery procedures for individual devices and services
Checking for message throughput
If the state of the LIU7 or MLIU is
ManB
15
Force the LIU7 or MLIU to busy by typing
>BSY
FORCE
and pressing the Enter key.
16
Return the LIU7 or MLIU to service
>RTS
and pressing the Enter key.
If the RTS command
passed, and the LIU7 is ISTb or InSv
failed, and the LIU7 is ManB or SysB
anything else
Note: Where the link interface unit is an MLIU, MLIU is shown in the MAP
display in place of LIU7.
17
Force the LIU7 or MLIU to busy by typing
>BSY
FORCE
and pressing the Enter key.
18
Reset the LIU7 or MLIU by typing
>PMRESET
and pressing the Enter key.
If the PMRESET command
passed, and the LIU7 is ManB
failed, and the LIU7 is ManB
Note: Where the link interface unit is an MLIU, MLIU is shown in the MAP
display in place of LIU7.
19
Reload the LIU7 or MLIU by typing
>LOADPM
and pressing the Enter key.
If the LOADPM command
passed
failed
DMS-100 Family NA100 Recovery Procedures LET0015 and up
Do
step 16
Do
step 36
step 17
step 54
Do
step 20
step 19
Do
step 20
step 54
4-21
(continued)

Advertisement

Table of Contents
loading

Table of Contents