5-42 Emergency power conservation recovery procedures
Emergency power conservation
Restoring the line modules to duplex operation
Restoring the line modules to duplex operation
At the LM controller shelf
1
2
3
297-8021-545 Standard 14.02 May 2001
WARNING
Potential extended equipment outage
Nortel recommends that you contact the Emergency
Technical Assistance Service (ETAS) to expedite recovery of
equipment.
WARNING
Potential loss of service or extended outage
Use this procedure to restore normal operation after you
perform the procedure for emergency power conservation.
Do not use this procedure or sections of this procedure for
equipment maintenance purposes.
WARNING
Static electricity damage
Wear a wrist strap that connects to the wrist-strap grounding
point of a frame supervisory panel (FSP) to handle circuit
cards. The wrist strap protects the cards against static
electricity damage.
Determine if the power converter is a NT2X70AE card.
If the power converter
is a NT2X70AE card
is not a NT2X70AE card
Determine if the FSP or MSP has circuit breakers.
If the FSP or MSP
has circuit breakers
does not have circuit breakers
Power up the converter in slot 20 as follows:
(continued)
Do
step 2
step 5
Do
step 3
step 4