5-166 Emergency power conservation recovery procedures
Emergency power conservation
Emergency shutdown of one SuperNode SE CM plane
19
20
297-8021-545 Standard 14.02 May 2001
IOD
IOC
0
1
2
3
STAT .
.
.
.
DIRP:
.
XFER:
.
NOP :
.
SLM :
.
SLM
0
1
Stat .
1
SLM 0
Note: The dots on the right side of the SLM Stat header indicate that SLM
0 and SLM 1 are in service.
WARNING
Possible loss of data recording services
The following step removes the SLM from service on the
inactive plane. Before you manually busy the inactive plane,
make sure that the SLM assumes the data recording services
on the active plane. The SLM provides the data recording
services on the inactive plane.
To manually busy the SLM, type
>BSY
and press the Enter key.
Example of a MAP response:
SLM 0 busy passed.
Note: The letter M on the right side of the SLM Stat header indicates that
the associated SLM is manually busy.
To access the PMC level of the MAP display, type
>CM;PMC
.
DVI :
.
.