2-92 System level recovery procedures
Recovering from a dead system in a SuperNode SE switch
34
35
36
37
38
297-8021-545 Standard 14.02 May 2001
Unlock the latches of the locking levers and carefully pull each NT9X74 card
toward you 25 mm (1 in.).
Leave the NT9X74 cards seated in the slots.
Locate the NT9X30 or NTDX16 power converters for the SCC LIS.
Note: Slots 4F and 36F on the SCC LIS contain the NT9X30 power
converters. Slots 1F, 4F, 33F, and 36F on the SCC LIS contain the
NTDX16 power converters.
Turn on the NT9X30 or NTDX16 power converters at the same time. Lift and
release the power switches on the faceplates of the converters to turn on the
NT9X30 or NTDX16 power converters.
Carefully slide the NT9X74 cards in slots 7F and 32F into the SCC LIS.
(continued)