5-104 Emergency power conservation recovery procedures
Emergency power conservation
Emergency shutdown of one DMS SuperNode CM plane
At the MAP terminal
9
10
11
12
13
14
297-8021-545 Standard 14.02 May 2001
RTIF response
JAM DONE
To drop synchronization, type
>DPSYNC
and press the Enter key.
Example of a MAP display
About to drop sync with CPU n active.
The inactive CPU is JAMMED.
Do you want to continue?
Please confirm ("YES", "Y", "NO", or "N"):
To confirm the command, type
>YES
and press the Enter key.
Wait until A1 flashes on the reset terminal for the inactive CPU.
Note: Allow 5 min for A1 to begin to flash.
To determine if the CM runs on the clock of the active CPU
>INSYNC
and press the Enter key.
Example of a MAP display:
CPU pair is NOT insync, CPU 0 is active.
CM is running on active CPU clock.
Memory Error Correction is ENABLED.
The inactive CPU IS Jammed.
If the CM
runs on the inactive clock
runs on the active clock
To run the CM on the clock of the active CPU, perform the procedure
Switching the clock source in Card Replacement Procedures . Complete the
procedure and return to this point.
To access the MC level of the MAP display, type
>MC
(continued)
Do
step 13
step 14