Nortel DMS-100 Manual page 213

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

4-6 Recovery procedures for individual devices and services
Checking for call completion
7
8
9
10
297-8021-545 Standard 14.02 May 2001
(continued)
and pressing the Enter key.
where
rteset_name
is the name of the routeset associated with the linkset chosenin step 4
Example input:
>POST
C
SSP100_RT
Example of a MAP display:
C7Routeset
SSP100_RT
Rte
State
Mode Cost Linkset
0
SysB
Assoc 0
1
SysB
Quasi 1
Determine which linksets in the posted routeset are causing problems.
If
one or more linksets are out of service
there are no more out-of-service linksets and there
are still routesets associated with call completion
problems
there are no more out-of-service linksets and there
are no more routesets associated with call completion
problems
Choose a linkset to work on.
Access the C7LKSET level of the MAP display by typing
>C7LKSET
and pressing the Enter key.
Post the linkset by typing
>POST
C
linkset_name
and pressing the Enter key.
where
linkset_name
is the name of the linkset chosen in step 8
SysB
Linkset
SSP100_LK
SSP101_LK
Transfer
State
Status
SysB
TFP
SysB
TFP
Do
step 8
step 4
step 51

Advertisement

Table of Contents
loading