10-120 Inverter Path Sensor On Jam RAP

The Inverter Path Sensor detected paper when closing the Inverter Cover or when the power
was switched on.
Initial Actions
Refer to BSD 10.8 and 10.12 for the following procedure.
Check for the following:
Clean the Inverter Path Sensor.
Ensure that connectors
P/J412B
and
and the Inverter Path Sensor, and there are no obvious crimped or broken wires.
Ensure the Inverter is closed. Switch the power Off then On.
Procedure
Enter dC330 010-125 Inverter Path Sensor. Press Start. The display indicates L.
Y
N
Go to
Flag 1
and
Flag 2
on BSD 10.8 and check the harness for a open circuit. If the har-
ness is good, replace the Inverter Path Sensor
If the fault code is present and can not be cleared, replace the IOT Drive PWB
fault code is not present and is occurring intermittently, go to
and check the harness for an intermittent open circuit. If the harness is OK, replace the Inverter
Path Sensor
(PL
2.24). If the problem continues, replace the IOT Drive PWB
Reissue
DocuColor 12/DCCS50
P/J151
are seated correctly on the IOT Drive PWB
(PL
2.24).
(PL
Flag 1
and
Flag 2
on BSD 10.8
(PL
9.2).

10-125 Inverter Path Sensor On Jam RAP

The Inverter Path Sensor did not actuate within the specified time after the Fuser Exit Sensor
actuated.
Initial Actions
Refer to BSD 10.8, 10.9 and 10.12 for the following procedure.
Check for the following:
Obstructions in the paper path
Proper Nip Drive force on the Inverter Rolls
Cheat the Front Door Interlock and check the function and the position of the Inverter
Gate and Inverter Gate Solenoid dC330 010-005 Inverter Gate Solenoid (Exit) and 010-
006 Inverter Gate Solenoid (Invert).
Clean the Inverter Path Sensor and Inverter Roll 2. Also, ensure that the sensor actuator
moves freely.
Ensure that connectors P/J412A,
Drive PWB and the Inverter Path Sensor, and there are no obvious crimped or broken
wires.
9.2). If the
Procedure
Enter dC330 010-125 Inverter Path Sensor. Press Start. Actuate the Inverter Path Sensor
actuator. The display changes from L to H.
Y
N
The display is a constant H.
Y
N
Go to
Flag 1
on BSD 10.8 and check the harness for an short circuit. If the harness is
good, replace the Inverter Path Sensor
Connect the meter from P/J412A-8 on the IOT Drive PWB to GND. Actuate the Inverter
Path Sensor actuator. The voltage at P/J412A-8 goes from less than +1.0 VDC when
the sensor is not actuated, to +5 VDC when the sensor is actuated.
Y
N
There is +5 VDC between P/J412A-9 and P/J412A-7 on the IOT Drive PWB.
Y
N
Go to
Flag 2
ness is good, replace the IOT Drive PWB
Go to
Flag 1
and
the harness is good, replace the Inverter Path Sensor
tinues, replace the IOT Drive PWB
Replace the IOT Drive PWB
Enter dC330 010-025 Inverter Roll Solenoid Nip. Press Start. The Release Solenoid ener-
gizes.
Y
N
+24 VDC is measured between P/J412A-14 and GND.
Y
N
+24 VDC is measured between P/J412A-13 and GND.
A
B
1/05
10-120 Inverter Path Sensor On Jam RAP, 10-125
2-143
P/J417A
and
P/J151
are seated correctly on the IOT
(PL
2.24).
on BSD 10.8 and check the harness for a short circuit. If the har-
(PL
9.2).
Flag 2
on BSD 10.8 and check the harness for an open circuit. If
(PL
(PL
9.2).
(PL
9.2).
2.24). If the problem con-
Status Indicator RAPs