6.6 Diagnosis, cont'd.
6.6:A Malfunction Indications,
cont'd.
Error No.
Nature of Error
62
CADT error
64
Host system hardware error
Intermec ColorCoder V4 – Service Manual Ed. 1
Probable Cause
Failure of gate array in Formatter
PCB.
Communication abnormality
with host. Interface cable abnor-
mality, SCSI interface PCB ab-
normality, faulty connection, etc.
Chapter 6
Troubleshooting
Corrective Action
Replace the Formatter PCB.
Check host, check interface cable con-
nection, replace SCSI interface PCB.
232