6.8 Function Troubleshooting, cont'd
6.8:A Measures to Take Against Malfunctions, cont'd.
No Ink Supply
Cause
Step
Connectors and Wir-
ing
Ink Cartridges
Pump Unit
Engine 1 PCB
Pump Unit
Intermec ColorCoder V4 – Service Manual Ed. 1
Check Point
1
Are the connections and wiring of the
following connectors in order?
• Pump Unit: J71, J76
• Engine 1 PCB: J302, J305
Is "EMPTY INK" displayed? Is there
2
ink in the ink cartridges?
Are the tube connections and routing
3
between pump units, needle blocks and
sub tanks, and to the tube stations, in
order? Are there any broken tubes?
Is the sensor plate stopping position of
4
the pressure cam home position sensor
in order?
5
Is the problem corrected when Engine 1
PCB is replaced?
6
Chapter 6
Troubleshooting
Result
Corrective Action
No
Reconnect and rewire the con-
nectors correctly.
Yes
Replace with new ink cartridge.
No
Reconnect and route the tubes
correctly.
No
Replace pump unit.
Yes
Finished.
No
Replace pump unit.
256