3 Maintenance
3.6.2. Cleaning, robot
Continued
Required equipment
Equipment, etc.
Steam cleaner
High pressure water
cleaner
Do's and don'ts!
The section below specifies some special considerations when cleaning the robot.
Always!
Never!
Foundry versions
In working environments, for example foundries, where the robot may be exposed to fluids
that dry to make a crusty surface, for example release agents, clean the cable harnesses so that
the crust does not damage the cables:
214
Art. no.
-
-
•
Always use cleaning equipment as specified above! Any other cleaning equipment
may shorten the life of paintwork, rust inhibitors, signs, or labels!
•
Always check that all protective covers are fitted to the robot before cleaning!
•
Never remove any covers or other protective devices before cleaning the robot!
•
Never use any cleaning agents, for example compressed air or solvents, other than
those specified above!
•
Never spray with a high pressure cleaner onto the sealing cup at the bottom of the
motor 6 spiral cable (item A in the figure Special points)!
•
Clean the spiral wound cables to motor 5 (item A in the figure
213!) with water and a cloth!
•
Clean the remaining sections of the cable harnesses as detailed above!
Note
•
Water pressure at nozzle: max. 2500 kN/m
(25 bar)
•
Type of nozzle: fan jet, min. 45° spread
•
Flow: max. 100 litres/min.
•
Water temperature: max. 80° C
•
Max. water pressure on enclosures: 50 kN/m
(0.5 bar)
•
Fan jet nozzle should be used, min. 45° spread
•
Flow: max. 100 litres/min.
3HAC022033-001 Revision: E
2
2
Special points on page