ABB IRB 7600 - 500/2.55 Product Manual page 318

Articulated robot
Hide thumbs Also See for IRB 7600 - 500/2.55:
Table of Contents

Advertisement

4 Repair
4.6.3. Replacement of motor, axis 3
Continued
316
Action
4.
NOTE!
Keep the old top cover with the air nipple
mounted.
5. Continue removal of the motor unit, according to
step 6 and forwards in section
page
311.
6. Fill the four screw recesses on the new motor with
Sikaflex. (After hardening, Sikaflex can be formed
with a knife)
7. Continue to refitt the new motor according to
section,
Refitting, motor on page
8. Perform a leak test according to
hoses (Foundry Prime) on page
Note
Removal, motor on
xx0600002875
313.
Inspection of air
176.
A: Motor unit
B: Sikaflex in screw
recesses
3HAC022033-001 Revision: E